ETA-THERM thermostatic balancing valve
ETA-THERM thermostatic balancing valve, union thread, 56 °C - 58 °C, figure 130 0G

ETA-THERM thermostatic balancing valve, union thread, 56 °C - 58 °C

figure 130 0G

  • control range 56 °C - 58 °C
  • thermostatic balancing valve for hydraulic balancing of very short circulation circuits from kv-min ≥ 0.05
  • for hydraulic balancing of hot water return systems (PWH-C), supports thermal disinfection
  • male union thread
ETA-THERM thermostatic balancing valve, FPT, 56 °C - 58 °C, figure 131 00

ETA-THERM thermostatic balancing valve, FPT, 56 °C - 58 °C

figure 131 00

  • control range 56 °C - 58 °C
  • thermostatic balancing valve for hydraulic balancing of very short circulation circuits from kv-min ≥ 0.05
  • for hydraulic balancing of hot water return systems (PWH-C), supports thermal disinfection
  • female pipe thread
UP-ETA-THERM thermostatic balancing valve, for flush-mounted installation, FPT, 56°C - 58°C, figure 540 02

UP-ETA-THERM thermostatic balancing valve, for flush-mounted installation, FPT, 56°C - 58°C

figure 540 02

  • control range 56 °C - 58 °C
  • thermostatic balancing valve for hydraulic balancing of very short circulation circuits from kv-min ≥ 0.05
  • for hydraulic balancing of hot water return systems (PWH-C), supports thermal disinfection
  • female pipe thread
UP-ETA-THERM thermostatic balancing valve, for flush-mounted installation, 56°C - 58°C, MAPRESS, figure 542 02

UP-ETA-THERM thermostatic balancing valve, for flush-mounted installation, 56°C - 58°C, MAPRESS

figure 542 02

  • control range 56 °C - 58 °C
  • thermostatic balancing valve for hydraulic balancing of very short circulation circuits from kv-min ≥ 0.05
  • for hydraulic balancing of hot water return systems (PWH-C), supports thermal disinfection
  • press connection for Geberit MAPRESS pipe
UP-ETA-THERM thermostatic balancing valve, for flush-mounted installation, 56°C - 58°C, San/Profipress, figure 544 02

UP-ETA-THERM thermostatic balancing valve, for flush-mounted installation, 56°C - 58°C, San/Profipress

figure 544 02

  • control range 56 °C - 58 °C
  • thermostatic balancing valve for hydraulic balancing of very short circulation circuits from kv-min ≥ 0.05
  • for hydraulic balancing of hot water return systems (PWH-C), supports thermal disinfection
  • press connection for Viega SANPRESS SST pipe and PROFIPRESS copper pipe
ETA-THERM thermostatic balancing valve, union thread, 62°C - 64 °C, figure 134 0G

ETA-THERM thermostatic balancing valve, union thread, 62°C - 64 °C

figure 134 0G

  • control range 62 °C - 64 °C
  • thermostatic balancing valve for hydraulic balancing of very short circulation circuits from kv-min ≥ 0.05
  • for hydraulic balancing of hot water return systems (PWH-C), supports thermal disinfection
  • male union thread
ETA-THERM thermostatic balancing valve, FPT, 62 °C - 64 °C, figure 136 00

ETA-THERM thermostatic balancing valve, FPT, 62 °C - 64 °C

figure 136 00

  • control range 62 °C - 64 °C
  • thermostatic balancing valve for hydraulic balancing of very short circulation circuits from kv-min ≥ 0.05
  • for hydraulic balancing of hot water return systems (PWH-C), supports thermal disinfection
  • female pipe thread
UP-ETA-THERM  thermostatic balancing valve, for flush-mounted installation, 62 °C - 64 °C, FPT, figure 540 62

UP-ETA-THERM  thermostatic balancing valve, for flush-mounted installation, 62 °C - 64 °C, FPT

figure 540 62

  • control range 62 °C - 64 °C
  • thermostatic balancing valve for hydraulic balancing of very short circulation circuits from kv-min ≥ 0.05
  • for hydraulic balancing of hot water return systems (PWH-C), supports thermal disinfection
  • female pipe thread

ETA-THERM thermostatic balancing valve

Hydraulic balancing to the bathroom

If it is necessary to draw off hot water immediately after opening a tap, whether because of increased hygiene requirements or for reasons of comfort, an automatic balancing valve is required to hydraulically balance the bathroom circulation system. As very low volume flows are required to maintain the temperature in a bathroom on account of reduced heat-dissipating surfaces, we have developed the ETA-THERM specifically for this case, whose kv value (kvmin = 0.05, kVmax = 0.4) is specially tailored to meet the needs of the bathrooms.

ETA-THERM is available in two versions

Installation is possible in the area of the individual shutoff in bathrooms as a flush-mounted or surface-mounted balancing valve.